– Upgrade existing control system to AC vector drives
– Replace operator station with touchscreen
– Add direct drive glue roll section
– Provide remote PLC I/O at machine
Industry
Corrugating
Location
Oklahoma
Components
Qty. (1) 75HP AC vector main drive
Qty. (1) 10HP AC vector bridge drive
Qty. (1) 10HP AC vector pre-conditioner drive
Qty. (1) 10HP AC vector glue roll drive
Qty. (1) Operator touchscreen
Qty. (1) Host PLC with profibus interface
Qty. (1) Remote PLC I/O panel
Features
• Replaced obsolete system comprised of DC drives and relay logic
• Single-vendor integrated system
• Profibus communication between all components
• Weekend installation